Specification | Description |
Solvent stocker |
Bottle | 3 L bottle × 1 |
Method | Hot-air circulation, PID control |
temperature | 40 ºC (5 ºC higher than room temperature) |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermal fuse (70 ºC) – circuit, Liquid drain |
Degass unit |
Method | Vacuum type |
Purge system |
Method | Syringe type |
Pump oven |
Method | Hot-air circulation |
Temperature | 40 - 50 ºC |
| (1 ºC step, 10 ºC higher than room temperature) |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermal fuse (70 ºC) – circuit, Gas sensor, Door sensor, Liquid drain |
Pump |
Flow mode | Parallel (Quick return) |
Flow rate range | 0.10 – 2.00 mL/min (0.01 mL step) |
| The reference flow rate is set in the ratio[1, 1/2, 1/4] |
| with the sample flow rate |
Accuracy | ± 2 % or ± 0.005 mL/min whichever greater |
| (H2O, 1 MPa or more, 1.2 mL/min or less) |
Precision | ± 0.2 % or ± 0.001 mL/min whichever greater |
| (H2O, 1 MPa or more, 1.2 mL/min or less) |
Pressure setting range | 0.0 – 15.0 MPa (0.1 MPa step) |
Drain valve | Electroactuation |
Auto sampler |
Measuring method | Loop measurement |
Sample loop | 300 µL (500 µL loop is attached, 10 – 500 µL loop is available) |
Reproducibility | CV 0.5 % |
Number of vials | 24 |
Vial volume | 10 mL |
Temperature | Aluminum block heating, PID control (sample table) |
control method | |
Range | 40 -220 ºC |
| (1 ºC step, 10 ºC higher than room temperature) |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermostat (250 ºC) – circuit, Door lock during table moving, |
| Sample cup sensor, Needle crash sensor, |
| Duct for local ventilation |
Valve box (Temperature control for injection valve) |
Method | Aluminum block heating, PID control |
Range | 40 - 220 ºC |
| (1 ºC step, 10 ºC higher than room temperature) |
Maximum pressure | 15 MPa |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermostat (250 ºC) – circuit, Gas sensor |
Column oven |
Method | Hot-air circulation, PID control |
Range | 40 - 220 ºC |
| (1 ºC step, 10 ºC higher than room temperature) |
Column capacity | 30 cm columns × 8, guardcolumn × 1, Inlinefilter × 1 |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermostat (250 ºC) – circuit, Gas sensors (2) , |
| Door lock at high temperature, Door sensor, Liquid drain |
RI detector |
Method | Bryce type double path and dual flow |
Light source | Tungsten lamp |
Flow cell | Made of quartz glass, volume; 10 µL, |
| Maximum pressure; 0.3 MPa |
Drift | 3 × 10-7 RIU/h (ODCB, 1.0 mL/min, 145 ºC) |
Noise | 1.5 × 10-8 RIU (ODCB, 1.0 mL/min, 145 ºC, response; 3 s) |
Temperature range | 40 - 220 ºC |
| (1 ºC step, 10 ºC higher than room temperature) |
Safety systems | Monitoring by temperature sensor – embedded software, |
| Thermostat (250 ºC) - circuit |
Drain stocker |
Bottle | 3 L bottle × 1 |
I/O terminals |
PC communication | USB |
Power supply ratings |
Voltage | AC 100 – 240 V |
Frequency | 50/60 Hz |
Power consumption | 1500 VA |
Dimensions and Weight |
Outside dimensions | 1000 (W) × 650 (H) × 500 (D) mm (excluding projections) |
Weight | 125 kg |